PVC insulated flame-retardent low smoke power cables with protective covering of БбШв type up to 1 kV. The cables meet the requirements of Specs. 16.К71-310-2001.
The cables are designed for power transmission and distribution in stationary equipment at alternating voltage 0,66 kV and 1kV, or at fixed voltage 1kV and 1,5 kV.
The cables are produced for industrial application and application in nuclear power stations by deliveries to home and export markets.
The cabels are designed for use in cable structures and areas, including nuclear power systems, class 3 or 4 as per classification ОПБ-88/97 (ПНАЭ Г-01-011-97).
Class of fire safety on classification НБП 248 - П1.7.2.1.
The cables are flame-retardent while bundled installation.
Type of climatization: UHL and T, allocation category 1 and 5 as per national standard GOST 15150-69.
| Operating temperature range (relative air humidity at the temperature up to +35°С-up to 98%) | -50°С to +50°С |
| Continuously permissible conductor operating heating temperature | +70°С |
| Max flame-retardent cable conductor temperature in case of short-circuit. | +400°С |
| Face-to-face length for nominal cross-section area: |
|
| Cable Installation and assembly without preheating | not lower -15°С |
| Minimal bending radius when laid: |
|
| Guaranty service life | 5 years from the date of commissioning, but not later than 6 months from the date of manufacturing. |
| Service life | 30 years |